Home
About Us
Issues
Authors
Reviewers
Users
Subscription
Our Other Journals
Site map
Aims and Scope
Salient Features
Editorial Board
Editorial Statements
Editorial-PeerReview Process
Publication Ethics & Malpractice
Ijars Performance
Journal Policy
Contact Us
Current Issue
Forthcoming
Article Archive
Access Statistics
Simple Search
Advanced Search
Submit an Article
Instructions
Assistance
Publication Fee
Paid Services
Apply As Reviewer
Acknowledgment
Register Here Edit Register
Register For Article Submission
Login Here Logout
Login For Article Submission
Annual
Buy One Issue
Payment Options
How to Order
JCDR
IJNMR
NJLM

 

Welcome : Guest

Users Online :

 

 

 

 

 

 

 

 

Original article / research

Year :2021 Month : March-April Volume : 10 Issue : 2 Page : RO11 - RO15 Full Version

Sonographic Placental Thickness Measurement: A Trustworthy Saviour for Foetal Age Estimation in Uncomplicated Pregnancy


Manish Kumar, Astha Nigam, Lalit Kumar, Shobha Mukherjee
1. Assistant Professor, Department of Radiodiagnosis, Rohilkhand Medical College and Hospital, Bareilly, Uttar Pradesh, India. 2. Junior Resident, Department of Radiodiagnosis, Rohilkhand Medical College and Hospital, Bareilly, Uttar Pradesh, India. 3. Professor and Head, Department of Radiodiagnosis, Rohilkhand Medical College and Hospital, Bareilly, Uttar Pradesh, India. 4. Professor, Department of Obstetrics and Gynaecology, Rohilkhand Medical College and Hospital, Bareilly, Uttar Pradesh, India.
 
Correspondence Address :
Dr. Astha Nigam,
G-Block, Room No. 37, Rohilkhand Medical College and Hospital,
Bareilly-243006, Uttar Pradesh, India.
E-mail: asthanigam1990@gmail.com
 
ABSTRACT

: Introduction: Placenta is a foeto-maternal organ playing a crucial role in endocrine, immunological, excretory, respiratory, and nutritional functions for the foetus. Gestational age estimation is usually based on the last menstrual period and ultrasonography. Many females having irregular menstruation present with unreliable last menstrual period and hence ultrasonography comes into play for correctly estimating the gestation. Various sonologically derived foetal parameters used for gestational age estimation are Crown Rump Length (CRL), Biparietal Diameter (BPD), Head Circumference (HC), and Abdominal Circumference (AC). The placental thickness measurement shows a direct correlation with the gestational age of the foetus till certain weeks of pregnancy, therefore could be utilised as a new and simple parameter in scenarios like term pregnancy where other parameters are unreliable.

Aim: To study the relationship between sonographic placental thickness measurement and gestational age of the foetus and also correlating other biometric parameters i.e., BPD, AC, femur length with placental thickness.

Materials and Methods: The present study was a cross-sectional study conducted in the Department of Radiodiagnosis, in collaboration with the Department of Obstetrics and Gynaecology, Rohilkhand Medical College and Hospital, Bareilly, Uttar Pradesh, India. Sample size constituted of 200 normal antenatal women in whom the placental thickness for various gestational age and correlation between placental thickness measurement with the gestational age of the foetus was done. Analysis of the relationship between placental thickness and other foetal parameters like BPD, femur length and AC was also assessed using Pearson correlation coefficient.

Results: Placental thickness measurements for gestational age 11-39 weeks were calculated; it gradually increased from 11.29 mm (mean) at 11 weeks to 35 millimeters (mm) (mean) at 39 weeks of gestation. Correlation coefficient was 0.9685 and p-value <0.01. Also, there was a significant positive correlation of placental thickness with other foetal biometry parameters like BPD, femur length and AC (p<0.001).

Conclusion: The measurement of placental thickness can become a key parameter for estimation of foetal age especially in cases where the exact duration of pregnancy is not known. It can also facilitate the detection of abnormal placental thickness associated with maternal and foetal complications in the early stages.
Keywords : Foetal biometry, Gestation, Last menstruation period, Ultrasonography
DOI and Others : DOI: 10.7860/IJARS/2021/46717:2621

Date of Submission: Sep 19, 2020
Date of Peer Review: Oct 28, 2020
Date of Acceptance: Nov 16, 2020
Date of Publishing: Apr 01, 2021

AUTHOR DECLARATION:
• Financial or Other Competing Interests: None
• Was Ethics Committee Approval obtained for this study? Yes
• Was informed consent obtained from the subjects involved in the study? Yes
• For any images presented appropriate consent has been obtained from the subjects. NA

PLAGIARISM CHECKING METH
 
INTRODUCTION

The placenta is a foeto-maternal organ which is partially formed by embryonic structures and partly from decidua. It plays a crucial role in endocrine, immunological, excretory, respiratory, and nutritional functions for the foetus. It prohibits microorganisms transfer from the maternal circulation to foetal circulation (1). The mature placenta weighs about 450 grams, is discoid, with a diameter of 15 to 20 cm (2). The placenta is smooth on its foetal surface, while its uterine surface appears rough and lobulated. Each lobe is composed of several cotyledons, which is the basic unit of the placenta (3). The foetoplacental-uterine circulation begins with deoxygenated blood pumped by the foetal heart through the ductus arteriosus into the descending aorta.

Donald I came up with localisation of the placenta by ultrasound in 1968 (4). Ultrasound since previous times have proven to be a most sensitive, rapid and safe modality for placental localisation and diagnosing abnormalities of the placenta (5),(6). Sonographic placentography performed routinely has now-a-days replaced old techniques like soft tissue radiography (7) and radioisotope scanning (8). The most common indication for obstetric ultrasound is the estimation of gestational age. Sonography plays an essential role in guiding the management of patients where many clinical decisions depend on gestational age. Many women are not able to recall the last menstrual period and have irregular menstrual history, therefore in such cases; ultrasonography plays a pivotal role in accurately estimating the gestational age.

Various sonologically derived foetal parameters used for gestational age estimation are CRL, BPD, HC, and AC. BPD could not be reliably measured in the foetus during the term and premature rupture of the membrane. So, for conditions like this and others there appeared a need for another parameter for supplementing the gestational age estimation with minimal error. Placental thickness measurement can be utilised as a new and simple parameter for the estimation of gestational age. The placental thickness measurement is relatively simpler and contributes to the management of foetuses at risk (9). Placental thickness can also be used as a gestational age indicator due to a linear increase in its thickness with advancing gestational age (10). The diagnosis of abnormal pregnancy from normal can be done based on placental thickness (11).

The purpose of the present study was to assess the relationship of placental thickness with gestational age and the growth pattern of the placenta with advancing gestational age. Also, the correlation of other foetal biometric parameters with placental thickness was analysed.
 
 
Material and Methods

This was a cross-sectional study, including 200 normal antenatal women. The study was done in the Department of Radiodiagnosis, collaborating with the Department of Obstetrics and Gynaecology, RMCH, Bareilly, Uttar Pradesh, India, from November 2018 to October 2019. Ethical committee clearance was obtained from the Institutional Ethical Committee with no.-IEC/31/2018/SEP. Written informed consent was obtained from all the subjects. Each woman with known last menstrual period and of gestational age between 11 to 39 weeks which was estimated ultrasonographically by derived foetal parameters was examined. The obtained mean values of placental thickness were correlated with the gestational age. In present study, a total of 200 women were included and the sample size (n) was calculated by the formula:

n= z2xpˆ(1-pˆ)/e2

Where, z is the z score, e is the margin of error, n is the population size and pˆ is the population proportion. For this study, the value of z was 1.96, e (error) was 0.05 and pˆ (population proportion) was 0.85 and the further sample calculated was 195.9216 which was rounded off and taken as 200.

Inclusion criteria: The antenatal women with no complications, comprising gestational ages from 11 weeks to 39 weeks, with known last menstrual period and regular menstruation were included.

Exclusion criteria: Patients diagnosed with hydrops foetalis, pregnancy induced hypertension, congenital anomalies, diabetes mellitus, intrauterine growth retardation, twin pregnancy, polyhydramnios and oligohydramnios. Placenta with pathological and morphological variations like placenta accreta, percreta, lobed placenta, succenturiate lobe, circumvallate placenta and placenta with variations in the insertion of umbilical cord-like marginal or battledore placenta and velamentous cord insertion, also, placenta with poor visualisation of the cord insertion site were excluded.

Methods: An ultrasound scan was done in the supine position using a real-time B-mode curvilinear array “GE LOGIC V5” ultrasound machine equipped with a 3.5 MHz transducer. Measurement of the placental thickness (in mm) was done at the level of the cord insertion site (12).

The cord insertion site of sonography appears as V-shape hypoechoic areas near the chorionic plate in the thickest portion of the placenta. It could also be sometimes seen as linear echoes perpendicular to the placental surface. The placental thickness was calculated at or near the mid-placental portion from the placental myometrial interface to the echogenic chorionic plate. Myometrium and sub-placental veins were excluded while obtaining measurements. The conventional biometric measurements like BPD, AC and femur length were also obtained along with placental thickness.

On an axial image foetal head BPD was measured from outer to inner margin of the calvarium at the level of the paired thalami, third ventricle, and cavum septum pellucidum using callipers. AC was measured at the level of the stomach and intrahepatic portion of the umbilical vein on an axial image of the foetal abdomen. The outer surface of the skin around the abdomen was included while measurement was done using elliptical callipers. The femur length measurement was done by placing the callipers on either ends of the ossified diaphysis. CRL measurement using callipers and calculations using Hadlock tables were utilised for obtaining the gestational age in the first trimester from 11 to 13 weeks of pregnancy (13).

Representative cases for acquiring data i.e., BPD, femur length, AC and placental thickness with cord insertion site (solid arrows) on sonography are shown in (Table/Fig 1),(Table/Fig 2).

In the second and third trimesters from 14 to 39 weeks of pregnancy gestational age is determined by combined foetal measurements of BPD, AC and femur length (14). Gestational age was calculated by the ultrasound machine based on Hadlock tables (13),(15),(16),(17). Measurements were acquired only once for each subject during the entire study.

The study analyses the correlation of placental thickness (in mm) measured with advancing gestational age (in weeks). In this study after obtaining the mean placental thickness, it was correlated with calculated gestational age from 11 to 39 weeks.

STATISTICAL ANALYSIS

The measured BPD, AC, femur length were also correlated with placental thickness values along with gestational age using Karl Pearson’s correlation using appropriate statistical methods for analysis and Statistical Package for the Social Sciences (SPSS) version 25 was used. Graphs and tables were generated using Microsoft Word and Excel.


 
 
Results

A total of 200 normal antenatal women were recruited for the study between the gestation age of 11 to 39 weeks. The age of the study population ranged from 18 to 36 years. The mean±standard deviation of the age of the entire group of cases studied was 25.3±3.6 years. The distribution of cases according to maternal age groups is presented in (Table/Fig 3).

The mean for each week of the gestational age was calculated and it was observed that the placental thickness gradually increased with the progressing gestational age. The mean placental thickness was 11.29 mm at 11 weeks of gestation and 35.0 mm at 39 weeks. Placental thickness nearly correlates with the gestational age in weeks from 11-35weeks of gestation and thereafter it is lowered by approximately 1-4 mm up till 39 weeks of gestation. In this study, minimum, placental thickness observed was 11.29 mm and the maximum was 35.0 mm. The mean placental thickness for each week of the gestational age along with the 95% confidence interval is presented in (Table/Fig 4).

Growth of the placenta was seen in a linear correlation with the advancement of gestational age till 35 weeks of gestation and there is a fall in the growth of the placenta from 36 weeks of gestation onwards. It is statistically studied from a 95% confidence interval that gestational age can be accurately predicted from the placental thickness measurements. For every week of increase in gestational age, there is an average increase of placental thickness by 0.9268 mm. The statistical data shows that placental thickness was directly related to gestational age with linear regression model yielding the following equation (11- 39 weeks) Placental thickness (in mm) = 0.9268 X Gestational age (in weeks) + 1.1395, (r = 0.9685), r = Pearson correlation coefficient depicted through (Table/Fig 5).

Linear regression analysis predicting foetal gestational age by sonography based on placental thickness was also studied and depicted in (Table/Fig 6). Dependent variable is gestational age.

The equation for prediction based on regression analysis is: Y (Gestational Age)= -0.4056+1.0457 X Placental Thickness (r=0.9681), by this equation, the gestational age can be predicted from the measurement of the placental thickness. The regression equation is Gestational Age (Y) on Placental Thickness (X) is shown in (Table/Fig 7).

Placental thickness with foetal biometry like BPD, femur length, AC also showed a positive correlation.

(Table/Fig 8) depicts the determinants of BPD, AC, femur length and gestational age by the placental thickness. The product-moment correlation coefficient of placental thickness with BPD, AC, femur length and gestational age were 0.9733, 0.9770, 0.9754 and 0.9839, respectively. The above correlation coefficients (r) were statistically very highly significant (p<0.001). The BPD was determined by the placental thickness as 94.73%. Similarly, The AC, femur length and GA were determined as 95.46%, 95.14% and 96.81%, respectively.

The growth variables estimated by placental thickness are BPD, AC, femur length with the help of the regression equations as shown in (Table/Fig 9),(Table/Fig 10),(Table/Fig 11).

 
 
Discussion

Since previous times, evaluation of the placenta has been routinely done for its position and timely diagnosis of various pathologies like placenta previa, premature placental abruption, etc., With the advancing ultrasonographic scan techniques, a detailed study of the placenta has been possible to know how placental morphology changes with the advancing gestational age.

In this study, 200 antenatal women with different gestational ages were studied for their placental thickness (in mm) and growth pattern and further calculations for the mean values of placental thickness obtained for different gestational ages from 11-39 weeks showed comparable results with the study done by Mittal P et al., (Table/Fig 12) (10). The correlation of the mean placental thickness measured in mm and the sonographic gestational age in weeks was evaluated.

Gottesfield KR and Hobbins JC in their study on 200 subjects, assessed that relationship of the placental thickness (in mm) with ultrasonographic gestational age (in weeks) shows a positive correlation (6). Similar results were obtained in this study where mean placental thickness has a positive correlation with the increasing gestational age.

Grannum et al., stated that there is an increase in placental thickness linearly until 33 weeks of gestation afterward it thins out (18). Similarly, Nyberg DA and Finberg HJ also in their study stated that the placental thickness in mm parallels the gestational age (19). Kobayashi M et al., described the correlation between placental thickness and gestational age in their study by placental growth curves and stated that the placental growth curve shows some flattening which begins just before the 35th week of gestation (5). Similarly in this study, it was evaluated that mean placental thickness increases with gestational age and shows a linear trend which paralleled with advancing gestational age (11-39 weeks) up to 35 weeks of gestation. An increase in the placental thickness from 35 weeks onwards falls gradually and lags behind the gestation age marginally by 1-4 mm. Present study results were also nearly consistent with the observation made by Mittal P et al., (10).

Hellman LM et al., in their study also analysed that the placenta stops to grow after 37 weeks and the thickness becomes lesser in the last four weeks (20). Hoddick WK et al., reviewed the sonograms performed on 200 singleton pregnancies and stated in their study that at no stage of pregnancy was the normal placenta greater than 4 cm in thickness (21). In this study at no point with advancing gestation, the placental thickness was above 4 cm. Elchalal U et al., analysed sonographically thick placenta (>4 cm or >90th centile) is associated with increased perinatal mortality and morbidity like foetal anomalies, small-for-gestational age (SGA) or large-for-gestational age (LGA) infants at term (22). In present study, none of the women had a placental thickness of more than 4 cm. Placental thickness <10th centile at 32 or 36 weeks could predict IUGR. Tongsong T et al., identified that thick placenta in about 93.3% of women with cytomegalovirus infection (23). This observation is of much help in antenatal management of suspected cases. Khanal UP et al., discussed in their prospective cross-sectional study that in normal pregnancy gestational age of a foetus can be predicted by measuring the placental thickness with a high confidence level (>95% at all gestational age) (24).

In this study also, it was found that a positive correlation existed between placental thickness and gestational age, which was statistically assessed by Pearson correlation coefficient (r= 0.9685 and p-value <0.01) and was also significant at a 95% confidence interval. The regression equation was calculated to measure gestational age with a placental thickness which was Y (Gestational age)=-0.4056 + 1.0457 X placental thickness (r=0.9681).

In the study done in the pregnant Nigerian women by Ohagwu CC et al., (25) in the second and third-trimester observation was made that placental thickness increased with gestational age in a nearly linear fashion. In the second and third trimester, a significant positive correlation was also seen between foetal parameters (BPD and AC) and placental thickness. This correlation strongly suggested that placental thickness can be utilised as a parameter for estimating gestational age. In our study, also placental thickness showed a significant correlation with other biometric parameters like BPD, FL and AC throughout the gestational period.

In the present study also the regression equation was calculated to measure BPD, AC and femur length with placental thickness respectively as; BPD=2.9449 (placental thickness)-10.988 (R2=0.9473), AC=11.46(placental thickness) -72.165 (R2=0.9546), FL=2.6444 (placental thickness)-19.636 (R2=0.9514). BPD, AC and femur length are not accurate in determining gestational age in the third trimester and hence this study was conducted to show, that placental thickness could be utilised as an additional parameter in estimating gestational age accurately in the second and third trimester.

Limitation(s)

Accurate measurements of placental thickness are obtained on a perpendicular scan of the placenta. Hence, if images are scanned obliquely or near the periphery of the placenta, it may spuriously suggest thinning. A 3D USG acquired placental volume measurement more accurately assesses placental size than placental thickness measurements. But, it is expensive and time-consuming. This study had a cross-sectional study design, which included observations on different individuals and the placental thickness was measured only once in each subject during the study. The sample size in this study was small for generating the nomogram of placental thickness for each gestational week and placental growth curves may be different for different population groups. As ultrasound measurements were obtained by a single observer and on the same machine, so there may be a chance for an observer bias (intra-observer variability) and instrumental bias.


 
 
Conclusion

A linear and direct correlation was found between placental thickness and gestational age; hence placental thickness (in mm) can be utilised as an important added parameter for estimating gestational age. It can also be correlated to other foetal biometric parameters like; BPD, AC and femur length along with gestational age therefore, can minimise the discrepancy even in the late second and third trimester where other acquired foetal measurements show discrepancies. Further, the regression equation derived from the placental thickness measurements can also be of great help to determine the gestational age of the foetus. Attention to technical details and correct correlation of placental thickness with gestational age can facilitate the detection of abnormal placental thickness associated with maternal and foetal complications in the early stages.
 
REFERENCES
1.
GuimarãesFilho HA, da Costa LL, Júnior EA, Nardozza LM, Nowak PM, Moron AF, et al. Placenta: Angiogenesis and vascular assessment through three-dimensional power Doppler ultrasonography. Archives of Gynaecol and Obstet. 2008;277(3):195.   [Google Scholar]
2.
Hamilton WJ. Boyd JD. Trophoblast in human uteroplacental arteries. Nature. 1966;212:906.   [Google Scholar]
3.
Crawford JM. Vascular anatomy of human placenta. Am J Obstet Gynaecol. 1962;84:1543.   [Google Scholar]
5.
Kobayashi M, Hellman LM, Fillisti I. Placental localisation by ultrasound. Am J Obstet Gyanecol. 1970;106:279.   [Google Scholar]
6.
Gottesfield KR, Thompson HE, Holmes JH, Taylor ES. Ultrasonic placentography – A new method of placenta localzation. Am J Obstet Gynecol. 1966;96:538.   [Google Scholar]
7.
Dippel AL, Brown WH. Roentgen visualisation of the placenta by soft tissue technique. Am J Obstet Gynecol. 1940;40:986-94.   [Google Scholar]
8.
Kohorn El, Walker RHS, Morrison J, Campbell S. Placental localization: A comparison between ultrasonic compound B scanning and radioisotope scanning. Am J Obstet Gynecol. 1969; l03(6):868-87.   [Google Scholar]
9.
Jauniaux E. Placental ultrasonographic measurements: What can we learn and is it worth doing routinely? Ultrasound Obstet Gynaecol. 1992;2:241-42.   [Google Scholar]
10.
Mittal P, Hooja N, Mehndiratta. Placental thickness- A sonographic parameter for estimating gestational age of the fetus. Ind J RadiolImag. 2002;12:553-54.   [Google Scholar]
11.
Ghosh A, Tang MH, Lam YH Fung E, Chan V. Ultrasound measurement of the placental thickness to detect pregnancies affected by homozygous alpha thalassaemia-1. Lancet. 1994;344:988-89.   [Google Scholar]
12.
Jauniaux E, Ramsay B, Campbell S. Ultrasonographic investigation of placental morphology and size during second trimester of pregnancy. Am J Obstet Gynaecol. 1994;170:130-37.   [Google Scholar]
13.
Hadlock FP, Shah YP, Kanon DJ, Lindsey JV. Fetal crown-rump length: Reevaluation of relation to menstrual age (5-18 weeks) with high-resolution real-time US. Radiology. 1992;182(2):501-05.   [Google Scholar]
14.
Jeanty P. Fetal biometry. In: Fleischer AC, Romero R, Manning FA, Jeanty P, James AE, Eds. The principles and practice of ultrasonography in Obstetrics and Gynaecology, 4th edition. Norwalk, Connecticut, Appleton and Lange. 1991;93.   [Google Scholar]
15.
Hadlock FP, Deter RL, Harrist RB, Park SK. Fetalbiparietal diameter: A critical re-evaluation of the relation to menstrual age by means of real-time ultrasound. J of Ultrasound in Med. 1982;1(3):97-104.   [Google Scholar]
16.
Hadlock FP, Deter RL, Harrist RB, Park SK. Fetal abdominal circumference as a predictor of menstrual age. Am J of Roentgenology. 1982;139(2):367-70.   [Google Scholar]
17.
Hadlock FP, Harrist RB, Deter RL, Park SK. Fetal femur length as a predictor of menstrual age: Sonographically measured. Am J of Roentgenology. 1982;138(5):875-78.   [Google Scholar]
18.
Granum PAT, Hobbins JC. The placenta. Radiol Clin North Am. 1982;20:353.   [Google Scholar]
19.
Nyberg DA, Finberg HJ. The placenta, placental membranes and umbilical cord. In: Newburgh DA, Mahony BS Pretorius DH, Eds Diagnostic ultrasound of fetal anomalies. St Louis, Mosby Year book publishers 1990; 623-675.   [Google Scholar]
20.
Hellman LM, Kobayashi M, Tolles W et al. Ultrasonic studies on the volumetric growth of human placenta. Am J Obstet Gynaecol. 1970;108:740.   [Google Scholar]
21.
Hoddick WK, Mahoney BS, Callen FW, Filly RA. Placental thickness. J Ultrasound Med. 1985;4:479-82.   [Google Scholar]
22.
Elchalal U, Ezra Y, Levi Y, Bar-Oz B, Yanai N, Intrator O, et al. Sonographically thick placenta: a marker for increased perinatal risk- A prospective cross-sectional study. J of Cli Ultrasound. 2000;21:268-72.   [Google Scholar]
23.
Tongsong T, Wanapirak C, Sirichotiyakue S. Placental thickness at mid pregnancy as a predictor of HbBarts disease. J on Prenatal Diagnosis. 1999;19:1027.   [Google Scholar]
24.
Khanal UP, Paudel S, Lohani B. Ultrasonographic measurement of placental thickness during pregnancy as a parameter for estimating gestational age of the foetus. Nepalese Journal of Radiology. 2017;7(10):13-18.   [Google Scholar]
25.
Ohagwu CC, Abu PO, Ezeokeke UO, Ugwa AC. Relationship between placental thickness and growth parameters in normal Nigerian fetuses. African Journal of Biotechnology. 2009;8(2):133-38.   [Google Scholar]
 
TABLES AND FIGURES
[Table/Fig-1] [Table/Fig-2] [Table/Fig-3] [Table/Fig-4] [Table/Fig-5]
[Table/Fig-6] [Table/Fig-7] [Table/Fig-8] [Table/Fig-9] [Table/Fig-10] [Table/Fig-11] [Table/Fig-12]
 
 
 

In This Article

  • Abstract
  • Material and Methods
  • Results
  • Discussion
  • Conclusion
  • References

Article Utilities

  • Readers Comments
  • Article in PDF
  • Citation Manager
  • How to Cite
  • Article Statistics
  • Link to PUBMED
  • Print this Article
  • Send to a Friend

Quick Links

REVIEWER
ACCESS STATISTICS
Home  |  About Us  |  Online First  |  Current Issue  |  Simple Search  |  Advance Search  |  Register  |  Login  |  Contact  |  Privacy Policy  |  Terms of Use
Author Support  |  Submit Manuscript  |  IJARS Pre-Publishing  |  Reviewer  |  Articles Archive  |  Access Statistics
©INTERNATIONAL JOURNAL OF ANATOMY RADIOLOGY & SURGERY (IJARS), ISSN : 2277-8543.
EDITORIAL OFFICE : 1/9, Roop Nagar, Delhi 11000. Phone : 01123848553

* This Journal is owned and run by medical professionals *